• Link to LinkedIn
ORS Laboratories are ISO 9001:2015 and AS9100D Certified| 1 (855) ORS-LABS
Oneida Research Services, Inc.
  • About Us
    • ORS Analytical Testing Services
    • 45 year anniversary
    • Career Opportunities
    • Locations
  • Services
    • Package Gas Analysis (RGA Testing)
      • HR-IVA® (High Resolution IVA Testing)
      • IVA® (Internal Vapor Analysis)
      • Gas Sampling Cylinder Analysis
      • Organic Mass Spectrometry – GC/MS
      • Delta-P Getter Sorption Qualification Testing
    • Hermeticity Testing
      • HSHLD® (High Sensitivity Helium Leak Detection)
      • Krypton-85 Fine and Gross Leak Testing
      • Helium Fine Leak Hermeticity Testing
      • Gross Leak Hermeticity Testing Processes
      • Leak Site Identification
      • Implanted Medical Devices
    • Material Outgassing Analysis
      • Material Outgassing Studies
      • UHV-EGA (Ultra-High Vacuum Evolved Gas Analysis)
      • ASTM E595 Outgassing Testing
      • Thermal Gravimetric Analysis-Mass Spectrometry (TGA-MS)
      • RGA Outgassing and Cleanliness Qualification Testing
    • PCB Testing
      • IPC-A-600 Inspection
      • IPC-TM-650 A/B and D Coupon Testing
      • IPC-TM-650 Thermal Stress, Plated-Through Holes
      • SIR & ECM Testing
    • Component Analysis
      • Destructive Physical Analysis (DPA)
      • Construction Analysis
      • Failure Analysis (FA)
      • Ion Milling
      • Acoustic Microscopy
      • Real Time X-Ray
      • 3D CT X-Ray
      • Acid Decapsulation of Electronic Components
      • Micro FT-IR Spectroscopy
      • Scanning Electron Microscopy (SEM) Inspection
      • X-Ray Fluorescence Elemental Analysis
    • Environmental Testing
      • Accelerated Bias Aging
      • Autoclave Testing
      • Cyclic Moisture Resistance
      • Highly Accelerated Stress Test (HAST)
      • Moisture Sensitivity Level Testing (MSL)
      • Preconditioning Test
      • Salt Atmosphere Testing
      • Steam Aging
      • Temperature Cycling Testing
      • Temperature Humidity Testing
      • Temperature Storage Testing
      • Thermal Shock Testing
    • Mechanical Testing
      • Constant Acceleration Testing
      • Fiber Integrity Testing
      • Mechanical Shock Testing
      • Particle Impact Noise Detection (PIND)
      • Physical Dimension Testing
      • Random Vibration Testing
      • Resistance to Solvents Testing
      • Solder Heat Resistance Test (SHRT)
      • Solderability Testing
      • Transportation Testing
      • Variable Frequency Vibration Testing
    • Electrical Testing
      • Intermittent Operating Life (IOL)
      • Insulation Resistance (IR)
      • Dielectric Withstanding Voltage (DWV)
      • Semiconductor Parametric Testing
      • Capacitance and Dissipation Factor (C&DF)
      • Optoelectronic Testing
  • Instrument Sales & Service
    • IVA® Model 210s Internal Vapor Analyzer
    • HSHLD® Model 310 High Sensitivity Helium Leak Detection System
    • Delta-P Model 410 Getter Sorption Analyzer
    • UHV-EGA Model 510 Ultra-High Vacuum Evolved Gas Analyzer
    • E595 Model 610 Outgassing Test System
    • CHLD 700H repair & upgrade
  • Resources
    • Blog
    • News
    • Publications
    • DLA Suitable Test Methods
    • Webinar
  • Tools
    • Moisture Calculator
    • Moisture Graph
    • Howl-Mann Equation
    • Oneida RAD™ Equation
    • Gas Evolution in Leaking Package
    • Solving for Oxygen Exchange Rate
  • Contact
  • Login
    • Customer Portal
    • ORS Cloud
  • Click to open the search input field Click to open the search input field Search
  • Menu Menu

Destructive Physical Analysis (DPA) Testing for Hybrid Microcircuits

Hybrid Microcircuits are typically a combination of discrete active and passive components that form a particular function essential to nearly all electronic systems.  Due to their wide-ranging applications, packaging of Hybrid Microcircuits will vary in construction design and materials to meet environmental, power, application or systems requirements. Multi-chip modules are included with hybrid assemblies and subjected to the same testing methods for DPA.

Typical Hybrid Microcircuit packages include hermetic metal packages with lid seam welds or solder seals, as well as lead glass frit seals. Non-hermetic plastic encapsulated hybrid packages are also used in some applications. Both are prevalent in Aerospace, Military and Automotive systems. Within the scope of Aerospace applications, Hybrid Microcircuit devices are subjected to qualification requirements to MIL-PRF-38534 and/or Methods for DPA to MIL-STD-1580 and MIL-STD-883.

TSON plastic encapsulated device

Hybrid Hermetic Package

TO-247 plastic encapsulated microcircuit

Hybrid Hermetic Package

SOT-23 plastic encapsulated microcircuit

Hybrid Hermetic Package

ORS Offers FAST Reliable Hybrid Microcircuit DPA

Hybrid Microcircuit(s) package variations require specific test methods to screen for manufacturing defects specified in DPA testing based military performance specifications (MIL-PRF) and design drawings. 

Hybrid Microcircuits for Aerospace applications must meet the DPA requirements MIL-STD-1580 Requirement 16 that specifies testing to primarily methods of MIL-STD-883. Specific test methods will vary based on applicability to the design or construction. All designs require external visual inspection, X-ray radiography and some form of internal visual inspection. Prohibitive metals analysis (PMA) for elemental constituents of packaging materials may also be applicable. 

Testing of hermetic packages requires testing to MIL-STD-883, which includes hermeticity testing to Method 1014 and Internal Gas Analysis (IGA) Method 1018, as well as wire bond strength and die shear testing Methods 2011 and 2019. SEM metal inspection to Method 2018 of integrated and semi-conductor die may also be required.

Plastic encapsulated devices typically require acoustic microscopy, dye impregnation for flux and moisture pathways with cross-sectional inspection of interfaces, bond pull (if applicable) and SEM metal test methods, depending upon metallization patterns as specified in Requirement 16.5 of Mil-Std-1580.

Cross-sectional view of secondary copper bond with acceptable effective bond area

Contact us for information about hybrid microcircuit testing

    * required field

    First Name *

    Last Name *

    Company *

    Business Email *

    Phone Number *

    How Can We Help

    I agree to the terms in the Privacy Policy. *

    Destructive Physical Analysis

    ORS has over 40 years of experience performing comprehensive testing designed to identify anomalies that can lead to field failure. 

    ORS DPA techniques for Hybrid Microcircuits have effectively revealed imperfections that include: improper package markings, hermetic seal failures related to lid seal and glass feed-through anomalies, bond wire placement, bi-metallic bonding intermetallic formations and wire-to-lid clearance, foreign material, die chip-outs and attachment voiding, plating deposit adhesion issues, chip capacitor termination formations, substrate thick film laser-trim and die-metal voiding, and contact-step thinning. 

    Non-Destructive Test Methods

    An important part of a Hybrid Microcircuit DPA are the applicable initial non-destructive testing methods – external visual inspection with physical dimensions/configuration compliance, X-ray radiography, acoustic microscopy for plastic encapsulated, hermeticity, particle-induced noise detection (PIND), prohibited material analysis (PMA) by X-ray fluorescence elemental analysis (XRF) or scanning electron microscopy with energy dispersive X-ray spectroscopy (SEM/EDS) along with fourier transform infrared microscopy (FTIR).* These methods can be essential to determining subsequent destructive test methods.

    *FTIR is commonly included in baseline DPA or Construction Analysis (CA) type analyses to document functional groups detected in mold compounds and other organic features (i.e., die conformal coating and leadframe adhesives).

    Cross-sectional view of secondary copper bond with acceptable effective bond area

    Exterior visual of package

    Y-axis X-ray View

    Z-axis X-ray view

    Glass frit seals

    Y-axis X-ray view

    Glass seal with square lead

    Destructive Analysis Methods of Hybrid Microcircuit Testing

    A complete DPA of a Hybrid Microcircuit would include destructive test methods such as Internal Gas Analysis (IGA) and internal visual inspection achieved by de-lidding/de-encapsulation. It may also include cross-sectioning, bond strength and die shear testing methods. Hybrid Microcircuit dies with expanded metal require scanning electron metal inspection (SEM). SEM with energy dispersive X-ray (EDS) analysis may be utilized for internal prohibitive materials analysis testing.

    Internal view of hybrid

    Termination attachment

    SEM image of attachment

    Internal view of hybrid

    Thick film resistor

    SEM image of attachment

    Internal view of hybrid

    Organic attachment

    Security compound bond

    Internal view of RF hybrid

    RF transistor die

    SEM image of chip-out

    Internal view of TO package

    Coil

    SEM of gold wire bonding

    Failure Modes of Hybrid Microcircuits that can be revealed by DPA:

    Failure modes of Hybrid Microcircuit microcircuits will depend and vary on construction and by application

    • Loss of hermeticity/glass and lid seals
    • Internal extraneous foreign material
    • Wire bonding damage/bimetallic intermetallic compounds  
    • Die scribing defects
    • Pure tin at external surfaces and internal surface
    • Undisclosed product changes

    Applicable Industries:

    • Space
    • Aerospace
    • Military Terrestrial
    • Automotive/Commercial
    • Mainframe Computers

    Military Standards:

    • MIL-PRF-38534
    • MIL-STD-1580/Req 16
    • MIL-STD-883 various Methods

    Summary of Hybrid Microcircuit Testing Methods

    MIL-STD-1580 Requirement 16
    MIL-STD-883 Test Methods
    • External Visual – Method 2009
      • Physical Dimensions
      • Lead Finish Verification
    • X-ray Radiography Method 2012
    • Particle Induced Noise Detection Method 2020
    • Acoustic Microscopy J-STD-035
    • (PEM) and/or Dye Impregnation Method 1013
    • Seal/Hermeticity Method 1014
    • Internal Gas Analysis Method 1018
    • Internal Visual Inspection Method 2017 and 2032
    • Bond Strength Testing Method 2011
    • SEM Metal Inspection Method 2018
    • Die Shear Testing Method 2019
    • Prohibited Materials Analysis Req. 9
    • Mechanical Testing
      • Constant Acceleration Testing
      • Fiber Integrity Testing
      • Mechanical Shock Testing
      • Particle Impact Noise Detection (PIND)
      • Physical Dimension Testing
      • Random Vibration Testing
      • Resistance to Solvents Testing
      • Semiconductor Parametric Testing and Characterization
      • Solder Heat Resistance Test (SHRT)
      • Solderability Testing
      • Transportation Testing
      • Variable Frequency Vibration Testing
    • Organic Mass Spectrometry
    • Package Gas Analysis (RGA)
      • IVA® (Internal Vapor Analysis)
      • HR-IVA® (High Resolution IVA® Testing)
      • Delta-P Getter Sorption Qualification Testing
      • Gas Sampling Cylinder Analysis
    • Component Analysis
      • Micro FT-IR Spectroscopy
      • Scanning Electron Microscopy (SEM) Inspection
      • X-Ray Fluorescence Elemental Analysis
      • Destructive Physical Analysis (DPA)
        • Destructive Physical Analysis (DPA) Testing for Capacitors
        • Destructive Physical Analysis (DPA) Testing for Crystals
        • Destructive Physical Analysis (DPA) Testing for Diodes
        • Destructive Physical Analysis (DPA) Testing for Filters
        • Destructive Physical Analysis (DPA) Testing for Fuses
        • Destructive Physical Analysis (DPA) Testing for Hybrid Microcircuits
        • Destructive Physical Analysis (DPA) Testing for Microcircuits
        • Destructive Physical Analysis (DPA) Testing for PEMS
        • Destructive Physical Analysis (DPA) Testing for Relays
        • Destructive Physical Analysis (DPA) Testing for Resistors
        • Destructive Physical Analysis (DPA) Testing for Thermistors
        • Destructive Physical Analysis (DPA) Testing for Transistors
        • Destructive Physical Analysis (DPA) Testing of Magnetic Components
      • Construction Analysis
      • Failure Analysis (FA)
      • Acid Decapsulation of Electronic Components
      • Ion Milling
      • Acoustic Microscopy
      • Steam Aging / Solderability
    • Hermeticity Testing
      • HSHLD® (High Sensitivity Helium Leak Detection)
      • Krypton-85 Fine and Gross Leak Testing
      • Helium Fine Leak Hermeticity Testing
      • Gross Leak Hermeticity Testing Processes
      • Leak Site Identification
      • Implanted Medical Devices
    • Electrical Testing
    • Material Outgassing Analysis
      • ASTM E595 Outgassing Services
      • RGA Outgassing and Cleanliness Qualification Services
      • Thermal Gravimetric Analysis-Mass Spectrometry (TGA-MS)
      • Ultra-High Vacuum Evolved Gas Analysis
      • Material Outgassing Studies
    • PCB Testing
      • Printed Circuit Board Inspection Services
      • SIR & ECM Testing
      • IPC-TM-650 A/B and D Coupon Testing
      • IPC-TM-650 Thermal Stress Testing
    • Capacitance and Dissipation Factor (C&DF)
    • Dielectric Withstanding Voltage (DWV)
    • Insulation Resistance (IR)
    • Intermittent Operating Life (IOL)
    • Optoelectronic Testing
    • Destructive Physical Analysis (DPA) Testing for Connectors
    • Environmental Testing
      • Accelerated Bias Aging Test
      • Autoclave Testing
      • Cyclic Moisture Resistance
      • Highly Accelerated Stress Test (HAST)
      • Moisture Sensitivity Level Testing (MSL)
      • Salt Atmosphere Testing
      • SMD Preconditioning Test
      • Steam Aging
      • Temperature Cycling Testing
      • Temperature Humidity Testing
      • Temperature Storage Testing
      • Thermal Shock Testing
    • X-Ray Inspection
      • X-Ray Computed Tomography (CT)
    • Consulting Services

    Test Submission Forms

    Component Form - NY
    Component Form - CO
    Material Outgassing Form - NY
    Mech/Environmental Form - PA
    PCB Coupon Form - CO
    RGA/Hermeticity Form - NY
    RGA/Hermeticity Form - CO

    Testing Methods

    MIL-STD
    ASTM
    JEDEC
    IEC
    TELCORDIA
    ICP
    Search Search

    Contact

    1 (855) ORS-LABS

    For general inquiries contact Krista Vivenzo

    kvivenzo@orslabs.com

    (315) 736-5480 ext. 2231

    Policies

    Terms of Use

    ORS Terms & Conditions of Purchase Order

    ORS Terms & Conditions of Quotation and Sale

    IVA®, HR-IVA® and HSHLD® are registered trademarks of Oneida Research Inc.
    Oneida Rad™ is a trademark of Oneida Research Services, Inc.

    New York

    Corporate Headquarters
    8282 Halsey Road
    Whitesboro, NY 13492 USA

    (315) 736-5480

    New York Office: DLA Suitability Letter

    Component Submission Form (NY)
    RGA/Hermeticity Submission Form (NY)
    Material Outgassing Submission Form (NY)

    Colorado

    8811 American Way, Suite 100
    Englewood, CO 80112 USA

    1 (855) ORS-LABS

    Colorado Office: DLA Suitability Letter

    Component Submission Form (CO)
    RGA/Hermeticity Submission Form (CO)
    PCB Coupon Submission Form (CO)

    France

    Oneida Recherche Services

    BP 163
    06903 SOPHIA ANTIPOLIS Cedex
    FRANCE

    +33 4 92 92 88 89

    European Office: DLA Suitability Letter

    Pennsylvania

    4201 Pottsville Pike
    Suite 420
    Reading, PA 19605 USA

    1 (855) ORS-LABS

    Pennsylvania Office: DLA Suitability Letter

    Mech/Enviro Submission Form (PA)

    Tools

    Howl-Mann Equation
    Oneida Rad™ Equation (Kr-85)
    Moisture Calculator
    Moisture Graph
    Gas Evolution in Leaking Package
    Solving for Oxygen Exchange Rate

    Certification

    ISO 9001:2015 & AS9100D Certified

    ISO/IEC 17025:2017 Accredited

    PJR Certification A2LA logo
    © Copyright 2025 - Oneida Research Services, Inc. | Privacy Policy | Terms of Use
    Scroll to top Scroll to top Scroll to top