• Link to LinkedIn
ORS Laboratories are ISO 9001:2015 and AS9100D Certified| 1 (855) ORS-LABS
Oneida Research Services, Inc.
  • About Us
    • ORS Analytical Testing Services
    • 45 year anniversary
    • Career Opportunities
    • Locations
  • Services
    • Package Gas Analysis (RGA Testing)
      • HR-IVA® (High Resolution IVA Testing)
      • IVA® (Internal Vapor Analysis)
      • Gas Sampling Cylinder Analysis
      • Organic Mass Spectrometry – GC/MS
      • Delta-P Getter Sorption Qualification Testing
    • Hermeticity Testing
      • HSHLD® (High Sensitivity Helium Leak Detection)
      • Krypton-85 Fine and Gross Leak Testing
      • Helium Fine Leak Hermeticity Testing
      • Gross Leak Hermeticity Testing Processes
      • Leak Site Identification
      • Implanted Medical Devices
    • Material Outgassing Analysis
      • Material Outgassing Studies
      • UHV-EGA (Ultra-High Vacuum Evolved Gas Analysis)
      • ASTM E595 Outgassing Testing
      • Thermal Gravimetric Analysis-Mass Spectrometry (TGA-MS)
      • RGA Outgassing and Cleanliness Qualification Testing
    • PCB Testing
      • IPC-A-600 Inspection
      • IPC-TM-650 A/B and D Coupon Testing
      • IPC-TM-650 Thermal Stress, Plated-Through Holes
      • SIR & ECM Testing
    • Component Analysis
      • Destructive Physical Analysis (DPA)
      • Construction Analysis
      • Failure Analysis (FA)
      • Ion Milling
      • Acoustic Microscopy
      • Real Time X-Ray
      • 3D CT X-Ray
      • Acid Decapsulation of Electronic Components
      • Micro FT-IR Spectroscopy
      • Scanning Electron Microscopy (SEM) Inspection
      • X-Ray Fluorescence Elemental Analysis
    • Environmental Testing
      • Accelerated Bias Aging
      • Autoclave Testing
      • Cyclic Moisture Resistance
      • Highly Accelerated Stress Test (HAST)
      • Moisture Sensitivity Level Testing (MSL)
      • Preconditioning Test
      • Salt Atmosphere Testing
      • Steam Aging
      • Temperature Cycling Testing
      • Temperature Humidity Testing
      • Temperature Storage Testing
      • Thermal Shock Testing
    • Mechanical Testing
      • Constant Acceleration Testing
      • Fiber Integrity Testing
      • Mechanical Shock Testing
      • Particle Impact Noise Detection (PIND)
      • Physical Dimension Testing
      • Random Vibration Testing
      • Resistance to Solvents Testing
      • Solder Heat Resistance Test (SHRT)
      • Solderability Testing
      • Transportation Testing
      • Variable Frequency Vibration Testing
    • Electrical Testing
      • Intermittent Operating Life (IOL)
      • Insulation Resistance (IR)
      • Dielectric Withstanding Voltage (DWV)
      • Semiconductor Parametric Testing
      • Capacitance and Dissipation Factor (C&DF)
      • Optoelectronic Testing
  • Instrument Sales & Service
    • IVA® Model 210s Internal Vapor Analyzer
    • HSHLD® Model 310 High Sensitivity Helium Leak Detection System
    • Delta-P Model 410 Getter Sorption Analyzer
    • UHV-EGA Model 510 Ultra-High Vacuum Evolved Gas Analyzer
    • E595 Model 610 Outgassing Test System
    • CHLD 700H repair & upgrade
  • Resources
    • Blog
    • News
    • Publications
    • DLA Suitable Test Methods
    • Webinar
  • Tools
    • Moisture Calculator
    • Moisture Graph
    • Howl-Mann Equation
    • Oneida RAD™ Equation
    • Gas Evolution in Leaking Package
    • Solving for Oxygen Exchange Rate
  • Contact
  • Login
    • Customer Portal
    • ORS Cloud
  • Click to open the search input field Click to open the search input field Search
  • Menu Menu

Hermeticity Testing for Implanted Medical Devices

How we identify potentially hazardous defects in hermetically sealed medical implants

Lack of adequate testing of implanted medical devices can have serious consequences. Cardiac pacemakers, cardiac defibrillators, cochlear implants, neurostimulators and other implantable devices require thorough quality control testing to verify safety and reliability.

Hermetically sealing internal medical devices against moisture and body fluids is crucial to the dependability of implantable devices. Medical devices use a variety of materials (metals, ceramics and plastics) and joining processes. Each type of seal process can be measured and verified to meet required leak rate limits.

Contact us with any questions you have about our hermeticity testing for implantable medical devices.

Contact ORS ›

Given the complexity of medical device implants and the number of variables, including design, materials and processes, medical device testing is imperative. ORS offers a wide range of advanced hermetic seal testing methods and instrumentation to detect the presence of moisture or leakage of outside air into medical implants. We want to ensure your implanted medical devices are protected from moisture and other gas contents that can cause the device to fail prematurely.

ORS’s accurate and reliable medical device testing is designed to uncover anomalies and avoid the need for recalls associated with untested or improperly tested devices. We provide peace of mind knowing that you’re working with industry experts and a world leader in package hermiticity and gas analysis testing. Whether you’re testing new products before market release, assessing current product performance or qualifying medical device shipments for conformance to a specification, you’ll be certain that entrapped water vapor, hydrogen or hermetic leaks won’t impact your development progress.

Internal Vapor Analysis

We use internal vapor analysis (IVA®) testing to determine the identities and quantities of gas within microelectronic components. This is also called residual gas analysis (RGA) testing or internal water vapor content (IWVC) testing. ORS’s engineers have refined the internal vapor analysis process, creating the industry’s most precise and reliable test methodology for hermetic seal integrity and internal moisture concentrations.

IVA® tests involve quantitatively measuring all primary and trace gases within hermetic components. IVA® testing focuses on seal quality control and control of outgassing from package piece parts and other materials, including adhesives and coatings used within the sealed enclosure.

ORS conforms to the highest standards when conducting IVA® testing. We can help whether you’re assessing current medical device performance, testing new products before market release or qualifying product shipments for conformance to a specification. With us, you’ll have absolute confidence that entrapped water vapor or hermetic leaks won’t impair your development progress, require costly replacements or negatively affect product performance.

In addition to standard IVA®, ORS offers high-resolution internal vapor analysis (HR-IVA®) testing, addressing the difficulties of measuring volatiles within increasingly smaller-volume (nanoliter) microelectronic packages.

Hermetic Package Testing

Ingress of moisture into hermetically sealed implanted medical devices can cause device errors or catastrophic failure. The crucial nature of this testing led ORS to perfect multiple primary hermetic test approaches to defend against moisture and contaminants that threaten a sealed system.

  • HSHLD® Testing: ORS’s high sensitivity helium leak detection (HSHLD®) method simultaneously measures helium and oxygen levels to determine fine and gross leaks. HSHLD® is a dry gross and fine method sensitive to 1 x 10-12 atm cc/sec, with cycle times of less than two minutes. This simplified, yet comprehensive test can measure leak rates of devices with internal free volumes as small as 0.001cc.
  • Krypton-85 Testing: This radioactive isotope method determines fine and gross leak rates in a high-reliability device, often used in critical medical devices, military components, commercial sensors and similar applications. The Krypton-85 method provides extremely fast test times, lower overall costs and testing in ambient conditions. It can also find thermally induced or pressure-induced hermetic failures.
  • Custom Leak Testing: ORS employs helium or other gases (Argon/Xenon/Oxygen/Krypton) to verify the fine leak seal integrity of any hermetic device. Custom leak test plans are available upon request.

Gas Chromatography and Mass Spectrometry

A natural complement to the IVA® test, gas chromatography/mass spectrometry (GC/MS) combines two techniques to identify unknown organic compounds detected during standard IVA® testing, plus compounds that may not have been detected by standard IVA®. ORS’s proprietary instrument design unites the separative features of gas chromatography with the identification capabilities of mass spectrometry, providing unprecedented speed and accuracy analyzing a variety of package or sample sizes and complexities.

GC/MS can be used to identify contamination, residual cleaning solvents, solder flux residue, epoxy curing problems, polymer degradation and additional breakdown byproducts with ppb-level sensitivity on devices with cavity sizes as small as <0.00001cc. Results can be used alone or combined with standard IVA® testing to determine if ongoing or propagated chemical reactions, corrosion or chemical deposition could affect long-term implanted medical device reliability. We also offer GC/MS testing for analytical applications focused on contamination identification, purity determination, outgassing studies, and identification of volatile and semi-volatile substances. Test results are qualitative for compound identification and semi-quantitative for concentration. They are customizable to your specific analysis needs. [/av_textblock] [av_hr class='default' icon_select='yes' icon='ue808' position='center' shadow='no-shadow' height='50' custom_border='av-border-thin' custom_width='50px' custom_margin_top='30px' custom_margin_bottom='30px' custom_border_color='' custom_icon_color='' av-desktop-hide='' av-medium-hide='' av-small-hide='' av-mini-hide='' id='' custom_class='' template_class='' av_uid='av-39mbri' sc_version='1.0'] [av_textblock size='' font_color='' color='' av_uid='av-n459zy']

Hermeticity Testing Services

HSHLD® Helium Fine and Dry Gross Leak Testing
Krypton-85 Fine and Gross Leak Testing
Helium Fine Leak Hermeticity Testing
Gross Leak Testing Processes
Leak Site Identification
Implanted Medical Devices

See for yourself!

Contact us for a demo or with any questions you have about advanced hermeticity testing methods for medical devices.

    Your Name (required)

    Your Email (required)

    Subject (required)

    Your Message

    I agree to the terms in the Privacy Policy. (required)

    • Mechanical Testing
      • Constant Acceleration Testing
      • Fiber Integrity Testing
      • Mechanical Shock Testing
      • Particle Impact Noise Detection (PIND)
      • Physical Dimension Testing
      • Random Vibration Testing
      • Resistance to Solvents Testing
      • Semiconductor Parametric Testing and Characterization
      • Solder Heat Resistance Test (SHRT)
      • Solderability Testing
      • Transportation Testing
      • Variable Frequency Vibration Testing
    • Organic Mass Spectrometry
    • Package Gas Analysis (RGA)
      • IVA® (Internal Vapor Analysis)
      • HR-IVA® (High Resolution IVA® Testing)
      • Delta-P Getter Sorption Qualification Testing
      • Gas Sampling Cylinder Analysis
    • Component Analysis
      • Micro FT-IR Spectroscopy
      • Scanning Electron Microscopy (SEM) Inspection
      • X-Ray Fluorescence Elemental Analysis
      • Destructive Physical Analysis (DPA)
        • Destructive Physical Analysis (DPA) Testing for Capacitors
        • Destructive Physical Analysis (DPA) Testing for Crystals
        • Destructive Physical Analysis (DPA) Testing for Diodes
        • Destructive Physical Analysis (DPA) Testing for Filters
        • Destructive Physical Analysis (DPA) Testing for Fuses
        • Destructive Physical Analysis (DPA) Testing for Hybrid Microcircuits
        • Destructive Physical Analysis (DPA) Testing for Microcircuits
        • Destructive Physical Analysis (DPA) Testing for PEMS
        • Destructive Physical Analysis (DPA) Testing for Relays
        • Destructive Physical Analysis (DPA) Testing for Resistors
        • Destructive Physical Analysis (DPA) Testing for Thermistors
        • Destructive Physical Analysis (DPA) Testing for Transistors
        • Destructive Physical Analysis (DPA) Testing of Magnetic Components
      • Construction Analysis
      • Failure Analysis (FA)
      • Acid Decapsulation of Electronic Components
      • Ion Milling
      • Acoustic Microscopy
      • Steam Aging / Solderability
    • Hermeticity Testing
      • HSHLD® (High Sensitivity Helium Leak Detection)
      • Krypton-85 Fine and Gross Leak Testing
      • Helium Fine Leak Hermeticity Testing
      • Gross Leak Hermeticity Testing Processes
      • Leak Site Identification
      • Implanted Medical Devices
    • Electrical Testing
    • Material Outgassing Analysis
      • ASTM E595 Outgassing Services
      • RGA Outgassing and Cleanliness Qualification Services
      • Thermal Gravimetric Analysis-Mass Spectrometry (TGA-MS)
      • Ultra-High Vacuum Evolved Gas Analysis
      • Material Outgassing Studies
    • PCB Testing
      • Printed Circuit Board Inspection Services
      • SIR & ECM Testing
      • IPC-TM-650 A/B and D Coupon Testing
      • IPC-TM-650 Thermal Stress Testing
    • Capacitance and Dissipation Factor (C&DF)
    • Dielectric Withstanding Voltage (DWV)
    • Insulation Resistance (IR)
    • Intermittent Operating Life (IOL)
    • Optoelectronic Testing
    • Destructive Physical Analysis (DPA) Testing for Connectors
    • Environmental Testing
      • Accelerated Bias Aging Test
      • Autoclave Testing
      • Cyclic Moisture Resistance
      • Highly Accelerated Stress Test (HAST)
      • Moisture Sensitivity Level Testing (MSL)
      • Salt Atmosphere Testing
      • SMD Preconditioning Test
      • Steam Aging
      • Temperature Cycling Testing
      • Temperature Humidity Testing
      • Temperature Storage Testing
      • Thermal Shock Testing
    • X-Ray Inspection
      • X-Ray Computed Tomography (CT)
    • Consulting Services

    Test Submission Forms

    Component Form - NY
    Component Form - CO
    Material Outgassing Form - NY
    Mech/Environmental Form - PA
    PCB Coupon Form - CO
    RGA/Hermeticity Form - NY
    RGA/Hermeticity Form - CO

    Testing Methods

    MIL-STD
    ASTM
    JEDEC
    IEC
    TELCORDIA
    ICP
    Search Search

    Contact

    1 (855) ORS-LABS

    For general inquiries contact Krista Vivenzo

    kvivenzo@orslabs.com

    (315) 736-5480 ext. 2231

    Policies

    Terms of Use

    ORS Terms & Conditions of Purchase Order

    ORS Terms & Conditions of Quotation and Sale

    IVA®, HR-IVA® and HSHLD® are registered trademarks of Oneida Research Inc.
    Oneida Rad™ is a trademark of Oneida Research Services, Inc.

    New York

    Corporate Headquarters
    8282 Halsey Road
    Whitesboro, NY 13492 USA

    (315) 736-5480

    New York Office: DLA Suitability Letter

    Component Submission Form (NY)
    RGA/Hermeticity Submission Form (NY)
    Material Outgassing Submission Form (NY)

    Colorado

    8811 American Way, Suite 100
    Englewood, CO 80112 USA

    1 (855) ORS-LABS

    Colorado Office: DLA Suitability Letter

    Component Submission Form (CO)
    RGA/Hermeticity Submission Form (CO)
    PCB Coupon Submission Form (CO)

    France

    Oneida Recherche Services

    BP 163
    06903 SOPHIA ANTIPOLIS Cedex
    FRANCE

    +33 4 92 92 88 89

    European Office: DLA Suitability Letter

    Pennsylvania

    4201 Pottsville Pike
    Suite 420
    Reading, PA 19605 USA

    1 (855) ORS-LABS

    Pennsylvania Office: DLA Suitability Letter

    Mech/Enviro Submission Form (PA)

    Tools

    Howl-Mann Equation
    Oneida Rad™ Equation (Kr-85)
    Moisture Calculator
    Moisture Graph
    Gas Evolution in Leaking Package
    Solving for Oxygen Exchange Rate

    Certification

    ISO 9001:2015 & AS9100D Certified

    ISO/IEC 17025:2017 Accredited

    PJR Certification A2LA logo
    © Copyright 2025 - Oneida Research Services, Inc. | Privacy Policy | Terms of Use
    Scroll to top Scroll to top Scroll to top